jump to content

Fachbereich Veterinärmedizin


Service-Navigation

    Publication Database

    Effects of isoflurane anaesthesia depth and duration on renal function measured with [99mTc]Tc-mercaptoacetyltriglycine SPECT in mice (2024)

    Art
    Zeitschriftenartikel / wissenschaftlicher Beitrag
    Autoren
    Schmitz-Peiffer, Fabian
    Lukas, Mathias
    Mohan, Ajay-Mohan
    Albrecht, Jakob
    Aschenbach, Jörg R. (WE 2)
    Brenner, Winfried
    Beindorff, Nicola
    Quelle
    EJNMMI research
    Bandzählung: 14
    Heftzählung: 1
    Seiten: Artikelnummer: 4
    ISSN: 2191-219x
    Sprache
    Englisch
    Verweise
    URL (Volltext): https://pubmed.ncbi.nlm.nih.gov/38180547/
    DOI: 10.1186/s13550-023-01065-3
    Pubmed: 38180547
    Kontakt
    Institut für Veterinär-Physiologie

    Oertzenweg 19 b
    14163 Berlin
    +49 30 838 62600
    physiologie@vetmed.fu-berlin.de

    Abstract / Zusammenfassung

    Background:
    The influence of anaesthetic depth and the potential influence of different anaesthetic beds and thus different handling procedures were investigated in 86 severe combined immunodeficient (SCID) mice using semi-stationary dynamic single photon emission computed tomography (SPECT) for kidney scintigraphy. Therefore, isoflurane concentrations were adjusted using respiratory rate for low (80-90 breath/min) and deep anaesthesia (40-45 breath/min). At low anaesthesia, we additionally tested the influence of single bed versus 3-mouse bed hotel; the hotel mice were anaesthetized consecutively at ~ 30, 20, and 10 min before tracer injections for positions 1, 2, and 3, respectively. Intravenous [99mTc]Tc-MAG3 injection of ~ 28 MBq was performed after SPECT start. Time-activity curves were used to calculate time-to-peak (Tmax), T50 (50% clearance) and T25 (75% clearance).

    Results:
    Low and deep anaesthesia corresponded to median isoflurane concentrations of 1.3% and 1.5%, respectively, with no significant differences in heart rate (p = 0.74). Low anaesthesia resulted in shorter aortic blood clearance half-life (p = 0.091) and increased relative renal tracer influx rate (p = 0.018). A tendency toward earlier Tmax occurred under low anaesthesia (p = 0.063) with no differences in T50 (p = 0.40) and T25 (p = 0.24). Variance increased with deep anaesthesia. Compared to single mouse scans, hotel mice in position 1 showed a delayed Tmax, T50, and T25 (p < 0.05 each). Furthermore, hotel mice in position 1 showed delayed Tmax versus position 3, and delayed T50 and T25 versus position 2 and 3 (p < 0.05 each). No difference occurred between single bed and positions 2 (p = 1.0) and 3 (p = 1.0).

    Conclusions:
    Deep anaesthesia and prolonged low anaesthesia should be avoided during renal scintigraphy because they result in prolonged blood clearance half-life, delayed renal influx and/or later Tmax. Vice versa, low anaesthesia with high respiratory rates of 80-90 rpm and short duration (≤ 20 min) should be preferred to obtain representative data with low variance.