    Efficacy of an automated technology at detecting early postpartum estrus events:
    Can we detect resumption of cyclicity? (2023)

    Art
    Zeitschriftenartikel / wissenschaftlicher Beitrag
    Autoren
    Borchardt, S. (WE 19)
    Burnett, T.A.
    Heuwieser, W. (WE 19)
    Plenio, J.L. (WE 16)
    Conceição, R.S.
    Cerri, R.L.A.
    Madureira, A.M.L.
    Quelle
    JDS communications
    Bandzählung: 5
    Heftzählung: 3
    Seiten: 225 – 229
    ISSN: 2666-9102
    Sprache
    Englisch
    Verweise
    URL (Volltext): https://linkinghub.elsevier.com/retrieve/pii/S2666910223001345
    DOI: 10.3168/jdsc.2023-0463
    Kontakt
    Tierklinik für Fortpflanzung

    Königsweg 65
    Haus 27
    14163 Berlin
    +49 30 838 62618
    fortpflanzungsklinik@vetmed.fu-berlin.de

    Abstract / Zusammenfassung

    The objective of this observational study was to evaluate the efficacy of a neck-mounted automated activity monitor (AAM)
    at detecting early postpartum resumed ovarian cyclicity. A total of 192 lactating cows (primiparous = 73 and multiparous = 119) were
    enrolled in this study. Cows were continuously monitored by a neck mounted AAM early postpartum (7 to 30 DIM). Calving was classi-
    fied as assisted (forced extraction of a calf) and unassisted (normal calving). Retained fetal membrane, metritis, hyperketonemia, clinical
    mastitis, and milk production were recorded. Cows were classified as healthy (i.e., no disease events) or sick (i.e., any disease event).
    Estrus events were alerted by the AAM using a proprietary algorithm set by the AAM company. Blood samples, from the coccygeal vein,
    were collected at 15, 18, 21, 24, 28 and 30 DIM for progesterone (P4) analysis. Resumption of cyclicity was considered when P4 concen-
    tration was ≥1ng/mL on any collection day. Cows were considered anovular when P4 concentration was <1ng/mL on all collection days.
    Cows were classified as: True Positive – P4 ≥ 1ng/mL and at least one estrus alert; False Positive – P4 < 1ng/mL and at least one estrus
    alert; True Negative – P4 < 1ng/mL and no estrus alerts and False Negative – P4 ≥ 1ng/mL and no estrus alerts. Statistical analyses were
    performed by frequency distribution and mixed effects logistic regression procedures on SAS. The specificity, sensitivity, accuracy, and
    positive predictive value of the sensor to detect cows which had resumed cyclicity were 84.0%, 34.1%, 52.1%, and 79.2%, respectively.
    Out of the 192 cows, 35.9% (69/192) were anovulatory and 37.5% (72/192) had no estrus events between 7 to 30 DIM. Healthy cows
    were more likely to resume cyclicity in early lactation compared with cows that were sick (78.3 ± 1.9 vs. 32.8 ± 3.1%, respectively)
    independent of parity. In conclusion, the sensor had a high specificity for detecting anovular cows, but it had lower sensitivity, and thus
    not effective at detecting cyclic cows, perhaps due to silent ovulation early postpartum.